Search results for "Plasma volume"

showing 10 items of 12 documents

Effect of obesity on left ventricular function studied by radionuclide angiocardiography

1991

Several studies have shown a significant association of obesity with cardiovascular morbidity and mortality. The present study was carried out to investigate central and systemic haemodynamics in overweight and moderate obese, but otherwise healthy subjects, and in a lean control group to determine whether obesity can influence left ventricular performance per se. In this study an attempt has been made to eliminate misleading factors, such as diabetes, lipid abnormalities and hypertension. A total of 67 subjects, 44 with overweight or moderate obesity and 23 lean healthy subjects, were included. Patients were divided into three groups according to BMI levels and Garrow's criteria as follows…

AdultHeart FailureMaleBlood VolumeSettore MED/09 - Medicina InternaHeart VentriclesBlood PressureStroke VolumeMiddle AgedSettore MED/11 - Malattie Dell'Apparato CardiovascolareBody Mass IndexRisk FactorsLeft ventricular funcion radionuclide angiography obesityHumansRegression AnalysisFemaleVascular ResistanceObesityCardiac OutputPlasma VolumeRadionuclide Angiography
researchProduct

Effects of marathon running on running economy and kinematics.

2000

The present study was designed to investigate interactions between running economy and mechanics before, during, and after an individually run marathon. Seven experienced triathletes performed a 5-min submaximal running test on a treadmill at an individual constant marathon speed. Heart rate was monitored and the expired respiratory gas was analyzed. Blood samples were drawn to analyze serum creatine kinase activity (S-CK), skeletal troponin I (sTnI), and blood lactate (B-La). A video analysis was performed (200 frames · s−1) to investigate running mechanics. A kinematic arm was used to determine the external work of each subject. The results of the present study demonstrate that after the …

AdultMalemedicine.medical_specialtyPhysiologySTRIDERunningNorepinephrineOxygen ConsumptionHeart RatePhysiology (medical)Internal medicineTroponin IHeart ratemedicineHumansOrthopedics and Sports MedicineLactic AcidTreadmillPlasma VolumeMuscle SkeletalRespiratory exchange ratioCreatine Kinasebusiness.industryTroponin IPublic Health Environmental and Occupational HealthBiomechanicsGeneral MedicineBiomechanical PhenomenaBreathingCardiologyRunning economyPhysical therapyFemalebusinessEnergy Metabolismhuman activitiesEuropean journal of applied physiology
researchProduct

Microcentrifuge or Automated Hematological Analyzer to Assess Hematocrit in Exercise? Effect on Plasma Volume Loss Calculations

2016

The assessment of plasma volume loss (∆PV) induced by exercise can be estimated from changes in hematocrit (Htc) and hemoglobin (Hb), and it is essential when investigating the metabolic or biologic response to exercise of circulating biomarkers. We aimed to ascertain whether the estimation of ∆PV may differ when Hb and Htc are determined by automated hematological analyzer (AHA) versus manual methods. Twenty-five healthy male subjects performed a maximal running incremental exercise. Blood samples were taken before exercise, immediately after exercise, and after a 30-min recovery. Hb and Htc (Htc-AHA) were determined by an AHA. Htc was also determined by microcentrifugation (Htc-M). The ∆P…

AdultMalemedicine.medical_specialtySpectrum analyzerSysmexAnalytical chemistryCentrifugationHematocritPlasma volumeIncremental exerciseHemoglobinsYoung Adult03 medical and health sciences0302 clinical medicineInternal medicinemedicineHumanshemoconcentrationhealth care economics and organizationsplasma volumeAutomation LaboratoryexerciseBiologic responsemedicine.diagnostic_testChemistryDill and Costill equation030229 sport sciencesMiddle AgedhemoglobinHemoconcentrationDill and Costill equation; Sysmex; exercise; hemoconcentration; hemoglobin; plasma volumeHealthy Volunteersdigestive system diseasesComputer Science ApplicationsMedical Laboratory TechnologyCirculating biomarkersHematocritCardiologyHemoglobinBiomarkers030215 immunologySLAS Technology
researchProduct

Acute Hemodynamic Responses to Combined Exercise and Sauna.

2020

AbstractThis study investigated acute hemodynamic, plasma volume and immunological responses to four loading protocols: sauna only, and sauna after endurance, strength or combined endurance and strength exercise. Twenty-seven healthy, slightly prehypertensive men (age 32.7±6.9 years) were measured at PRE, MID (after exercise), POST, POST30min and POST24h. The measurements consisted systolic and diastolic blood pressure, heart rate, body temperature and concentrations of high-sensitive C-reactive protein, white blood cells and plasma volume measurements. Endurance+sauna showed significant decreases in systolic blood pressure at POST (–8.9 mmHg), POST30min (–11.0 mmHg) and POST24h (–4.6 mmHg)…

AdultMalemedicine.medical_specialtyStrength trainingNeutrophilsHemodynamicsPhysical Therapy Sports Therapy and RehabilitationBlood Pressure030204 cardiovascular system & hematologyPrehypertensionBody TemperatureSteam Bath03 medical and health sciencesLeukocyte Count0302 clinical medicineEndurance trainingHeart RateInternal medicineHeart ratemedicineHumansOrthopedics and Sports MedicineExercise physiologyPlasma VolumeExercisebusiness.industryHemodynamicsResistance Training030229 sport sciencesHypoxia (medical)Blood pressureC-Reactive ProteinCardiologyPhysical Endurancemedicine.symptombusinessPhysical Conditioning HumanInternational journal of sports medicine
researchProduct

Aquatic cycling-What do we know? A scoping review on head-out aquatic cycling

2017

Over the past few years, aquatic cycling has become a trending fitness activity. However, the literature has not been reviewed exhaustively. Therefore, using scoping review methodology, the aim of this review was to explore the current state of the literature concerning aquatic cycling. This study specifically focused on study designs, populations and outcomes. A comprehensive search of seven databases (PubMed, MEDLINE, Cinahl, Embase, PEDro, Web of Science, WorldCat) was conducted up to 30th September 2016. GoogleScholar, World Cat, ResearchGate, specific aquatic therapy websites and aquatic therapy journals were searched to identify additional literature. Full-text publications in English…

MalePhysiologyMaternal HealthPsychological interventionlcsh:MedicineBlood PressureVascular MedicineDatabase and Informatics Methods0302 clinical medicinePregnancyHeart RateMedicine and Health SciencesMedicinePublic and Occupational HealthDatabase Searchinglcsh:ScienceMusculoskeletal SystemMultidisciplinaryTemperatureObstetrics and GynecologyResearch AssessmentSports ScienceExercise TherapyBody Fluids3. Good healthBloodSystematic reviewMeta-analysisLegsFemaleAnatomyAEROBIC EXERCISECyclingWATER IMMERSIONPREGNANT-WOMENSportsResearch ArticleSystematic ReviewsLEG EXERCISEPOWERCardiologyMEDLINECINAHLResearch and Analysis Methods03 medical and health sciencesCOLD-WATEREnvironmental healthHumansAquatic therapyCENTRAL BLOOD-VOLUMESports and Exercise MedicinePlasma VolumeTHERMAL RESPONSESExercisebusiness.industryClinical study designLimbs (Anatomy)lcsh:RWaterBiology and Life SciencesPhysical Activity030229 sport sciencesRATE-VARIABILITYPHYSIOLOGICAL-RESPONSESPhysical FitnessWomen's Healthlcsh:Qbusiness030217 neurology & neurosurgeryPLOS ONE
researchProduct

Blood rheology effect of submaximal exercise on young subjects

2013

Nowadays cardiac and metabolic diseases are a matter of concern. Exercise is a valid treatment and method of prevention for not only adults, but also young subjects. Physical activity causes transient blood rheology impairment in adults. However little is known about the effects of exercise on blood flow characteristics in young subjects. The aim of the study was to assess the effects of a light aerobic exercise session on blood rheology in young subjects. Ten young subjects (aged 12-16 years) performed 1 hour of submaximal aerobic exercise (70% HRmax). Blood samples were drawn just before and after exercise. We determined blood and plasma viscosity, fibrinogen, erythrocyte deformability an…

Malemedicine.medical_specialtyAdolescentPhysiologyBlood viscosityHematocritFibrinogenErythrocyte aggregationPhysiology (medical)Internal medicinemedicineHumansAerobic exerciseErythrocyte deformabilityPlasma VolumeChildExercisemedicine.diagnostic_testbusiness.industryFibrinogenHematologyBlood flowHematocritHemorheologyCardiologyPhysical therapyFemaleHemorheologyCardiology and Cardiovascular Medicinebusinessmedicine.drugClinical Hemorheology and Microcirculation
researchProduct

Lethal Anaphylactic Reaction to Intravenous Gelatin in the Course of Surgery

2016

Plasma volume expanders (PVEs) are widely used to increase circulating blood volume. Gelatins used as PVEs are heterogeneous mixtures of polypeptides, usually prepared by hydrolysis of bovine collagen containing large amounts of proline and hydroxyproline residues. It has been shown that gelatins can cause anaphylactic reactions. We describe the case of a 73-year-old man who during surgery for intestinal obstruction presented a lethal anaphylactic reaction after the administration of a PVE containing gelatin lysate. The reaction occurred 10 minutes after the start of plasma expander infusion. Then, patient became comatose, and he died without awakening after 76 days. Necroptic aspects and h…

Malemedicine.medical_specialtyBovine collagenfood.ingredientPlasma SubstitutesBlood volumeAdministration IntravenouPlasma expanderGelatinDrug Hypersensitivity03 medical and health sciencesHydroxyprolinechemistry.chemical_compoundFatal Outcome0302 clinical medicinefoodSettore MED/43 - Medicina LegaleAnaphylaximedicineHumansPharmacology (medical)030212 general & internal medicineComaAdverse effectAnaphylaxisAgedPharmacologyIntravenous Gelatinbusiness.industryPlasma SubstituteAnaphylactic reactionAnaphylactic reactionsGeneral MedicineAdverse reactionPlasma expanderSurgeryLethal Anaphylactic Reaction030228 respiratory systemchemistryPlasma volume expandersAnesthesiaGelatinAdministration IntravenousPlasma volume expanders Lethal Anaphylactic Reaction Intravenous GelatinbusinessIntestinal ObstructionHumanAmerican Journal of Therapeutics
researchProduct

Variations of plas14a benin activity and aldostehone levels in the rat after administration of saline, chrystalloid and colloid solutions

1976

Abstract The data reported in the present paper refer to quantitative variations of plasma renin activity (PRA.) and of plasma aldosterone levels in rats after adiministration of saline, chrystalloid and colloid solutions. In our experimental conditions PRA and plasma aldosterone levels were shown to increase significantly after administration of distilled water and glucose solution. Variations of PRA and plasma aldosterone levels were only slight when plasma volume was made to increase due to administration of polyvinylpirrolidone solution. PRA, instead, was significantly lower in rats having received saline salution.

Pharmacologymedicine.medical_specialtyanimal structuresChemistrymedicine.medical_treatmentAldosterone levelsurologic and male genital diseasesPlasma volumePlasma renin activityfemale genital diseases and pregnancy complicationsColloidEndocrinologyDistilled waterInternal medicinemedicineSalinehormones hormone substitutes and hormone antagonistscirculatory and respiratory physiologyPharmacological Research Communications
researchProduct

Structural assessment of the EU-DEMO WCLL Central Outboard Blanket segment under normal and off-normal operating conditions

2021

Abstract Within the framework of the EUROfusion design activities concerning the EU-DEMO Breeding Blanket (BB) system, a research campaign has been carried out at the University of Palermo with the aim of investigating the structural behaviour of the DEMO Water-Cooled Lithium Lead (WCLL) Central Outboard Blanket (COB) segment. The assessment has been performed considering three different loading scenarios: the Normal Operation (NO), the Over-Pressurization (OP) and the Upward Vertical Displacement Event (VDE-up). In particular, NO scenario represents the loading case referring to the nominal operating conditions, whereas the OP scenario refers to the loading conditions due to an in-box LOCA…

business.industryDesign activitiesMechanical EngineeringFEM analysisStructural engineeringVDEBlanketPlasma volumeVertical motionFinite element methodWCLLNuclear Energy and EngineeringPlasma chamberGeneral Materials ScienceVertical displacementBreeding blanketbusinessDEMOGeologySettore ING-IND/19 - Impianti NucleariCivil and Structural EngineeringEvent (probability theory)
researchProduct

Corrected whole blood biomarkers - the equation of Dill and Costill revisited.

2018

Abstract An exercise bout or a dehydration often causes a reduction in plasma volume, which should be acknowledged when considering the change in biomarkers before and after the plasma changing event. The classic equation from Dill and Costill (1974, J. Appl. Physiol., 37, 247–248) for plasma volume shift is usually utilized in such a case. Although this works well with plasma and serum biomarkers, we argue in this note that this traditional approach gives misleading results in the context of whole blood biomarkers, such as lactate, white cells, and thrombocytes. In this study, we demonstrate that to calculate the change in the total amount of circulating whole blood biomarker, one should u…

medicine.medical_specialtyPhysiologyContext (language use)030204 cardiovascular system & hematologyPlasma volumeta311103 medical and health sciencesHemoglobins0302 clinical medicineSerum biomarkersPhysiology (medical)Internal medicineMembrane PhysiologymedicineHumansplasma changePlasma Volumeta315Exercisecorrection formulaWhole bloodOriginal ResearchDehydrationbusiness.industryEndurance and PerformanceDill and Costill equationveri030229 sport sciencesBiomarkerEndocrinologymarkkeritBiomarker (medicine)veriplasmaHemoglobinsense organsCellular PhysiologybusinessAlgorithmsBiomarkersPhysiological reports
researchProduct